Swyddogaeth | Marc | Diffiniad |
Terfynell mewnbwn pŵer | V+ | Cyflenwad pŵer DC positif mewnbwn |
V- | Cyflenwad pŵer DC mewnbwn negatif | |
Terfynell Modur 1 | A+ | Cysylltu pennau dirwyn cam 1 A y modur |
A- | ||
B+ | Cysylltwch gam B y modur 1 â'r ddau ben | |
B- | ||
Terfynell Modur 2 | A+ | Cysylltu pennau dirwyn cam 2 A y modur |
A- | ||
B+ | Cysylltwch gam B y modur 2 â'r ddau ben | |
B- | ||
Porthladd rheoli cyflymder | +5V | Potentiometer pen chwith |
AIN | Terfynell addasu potentiometer | |
GND | Potentiometer pen dde | |
Dechrau a gwrthdroi (mae angen cylched fer rhwng AIN a GND os nad ydynt wedi'u cysylltu â photentiomedr) | OPTO | Terfynell bositif cyflenwad pŵer 24V |
DIR- | Terfynell gwrthdroi (0V) | |
ENA- | Terfynell gychwyn (0V) |
Cerrynt brig (A) | Gwerth dilys | SW1 | SW2 | SW3 | Sylw |
0.3 | 0.2 | ON | ON | ON | Gellir addasu gwerthoedd cyfredol eraill |
0.5 | 0.3 | OFF | ON | ON | |
0.7 | 0.5 | ON | OFF | ON | |
1.0 | 0.7 | OFF | OFF | ON | |
1.3 | 1.0 | ON | ON | OFF | |
1.6 | 1.2 | OFF | ON | OFF | |
1.9 | 1.4 | ON | OFF | OFF | |
2.2 | 1.6 | OFF | OFF | OFF |
Ystod cyflymder | SW4 | SW5 | SW6 | Sylw |
0~100 | ON | ON | ON | Gellir addasu ystodau cyflymder eraill |
0~150 | OFF | ON | ON | |
0~200 | ON | OFF | ON | |
0~250 | OFF | OFF | ON | |
0~300 | ON | ON | OFF | |
0~350 | OFF | ON | OFF | |
0~400 | ON | OFF | OFF | |
0~450 | OFF | OFF | OFF |